Conditioned per atsm c1289 test method astm c518 1 2.
Rigid foam r value per inch.
Falls in the middle of the three types of rigid foam insulation in both cost and r value used most in walls or below grade applications recyclable and at about r 5 per inch costs around 42 per sq.
Expanded polystyrene insulation is similar to the foam used for packing peanuts and it s typically used for insulated concrete forms also knows as icf s.
Most varieties of foam have a higher r value per inch than fiberglass cotton or cellulose.
For a 1 in thick 4 8 panel comes unfaced or with a number of different plastic facings.
R value chart for enerfoil tm rigid foam faced insulation.
Additional r value for a masonry wall constructed using these materials needs to add the insulating value of additional wall components typically included such as 1 solid foam polyisocyanurate r 8 extruded polystyrene r 5 expanded polystyrene r 4 or 1 of perlite r 2 7 and for an exterior air film winter no wind r 0 17 an interior.
Thickness inches r value in i p imperial rsi r value in metric 0 5.
Eight inches of poor quality insulation may have a higher and better r value than one inch of top.
Rmax r matte plus 3 1 2 in.
Rigid foam can be used in walls roofs and foundations for retrofits or new construction.
There are three main types of rigid foam insulation.
Expanded polystyrene eps extruded polystyrene xps and polyisocyanurate.
Expanded polystyrene foam eps is the cheapest and least used foam board product on the market.
The r value for foamular xps insulation is provided from testing at two mean temperatures 40ºf and 75ºf and from two aging conditioning techniques 180 day real.
Open cell polyurethane spray foam 3 5 inches thick 12 6.
Rigid foam r values range from r 1 for 1 4 inch thick sheathing panels to r 15 for 3 inch thick panels.
The time of testing.
R value cost sq.
R 3 2 polyisocyanurate rigid foam insulation board r matte plus 3 thermasheath 3 is rigid foam r matte plus 3 thermasheath 3 is rigid foam plastic thermal insulation board.
It s made of environmentally sound closed cell polyisocyanurate foam bonded to a durable white matte non glare aluminum facer and a reflective reinforced aluminum facer.
Fiberglass insulation packs in more r value per cubic inch than rigid foam insulation does.
In comparison an inch of blown fiberglass insulation has an r value of 3 1 3 4 and an inch of blown cellulose in an attic has an r value of 3 2 3 7.
As a benchmark one inch of solid wood has an r value of 1.
Loose fill such as fiberglass cellulose mineral wool 8 23 inches thick 30 50.
Along with knowing the r value of a particular insulation it is also important to calculate the r value of a total system.
This product typically has an r value of 3 6 to 4 0 per inch of thickness.